AC Load Breakers Instruction Sheet
PN: 64-0043 Rev A 1
Magnum Energy, Inc.
2211 West Casino Rd.
Everett, WA 98204
www.magnumenergy.com
Figure 1, Physical Dimensions
Introduction
The BR-AC30D and BR-AC60S are AC breakers that are used as the disconnect
switch and overcurrent protection device for the inverters AC input. These
circuit breakers come equipped with slots in the molded case for attaching
mounting brackets/feet, which allows them to be easily back-mounted to the
breaker mounting plate inside the MP (Magnum Panel) enclosure.
Depending on the part number, the breaker is either a 30 amp dual pole
(PN: BR-AC30D) or a 60 amp single pole (PN: BR-AC60S), general purpose
Square-D QOU™ type, back-mountable, AC circuit breaker.
Square-D, Type QOU
Breaker Speci cations
Approvals:
UL489 Listed - CSA C22.2 #5.1
Certi ed
Continuous Current:
• QOU circuit breakers should be
applied (per the NEC) to carry 80%
of their continuous current ratings
as indicated on the handle of each
circuit breaker. BR-AC30D dual pole
= 30 amps (24 amps derated); BR-
AC60S single pole = 60 amps (48
amps derated)
Recommended Torque:
Using Terminal Screw = 43 in. lbs.
Physical:
Weight: BR-AC60S = ~5.9 oz.
(167.3 g); BR-AC30D = ~12 oz.
(340.2 g)
Terminals: Box-type lugs with
slotted terminal screws. UL listed
and CSA certi ed to accept solid or
stranded #14 to #2 AWG copper or
aluminum conductors. These lugs
are UL listed to be used with wire
rated at 140°F, 167°F and 194°F
(60°C, 75°C and 90°C), sized
according to the NEC 176°F (75°C)
temperature rating.
Mounting: Attaches to the breaker
mounting plate with #8-32 x 1/4”
(T20 drive) Torx screws using the
included eld installable mounti
ng
brackets/feet.
WARNING: During normal operation the terminals, busbars, and
electrical components inside the MP may be energized - DO NOT
TOUCH. Disconnect all power sources before removing cover.
A
B
C
D
BR-AC30D
BR-AC30D BR-AC60S
A 4.1” (10.4 cm) 4.1” (10.4 cm)
B 1.5” (3.8 cm) 0.75” (1.9 cm)
C 2.4” (6.1 cm) 2.4” (6.1 cm)
D 4.6” (11.7 cm) 4.6” (11.7 cm)